Search results for " ECG"
showing 10 items of 28 documents
Software-based analysis of 1-hour Holter ECG to select for prolonged ECG monitoring after stroke.
2020
Abstract Objective Identification of ischemic stroke patients at high risk for paroxysmal atrial fibrillation (pAF) during 72 hours Holter ECG might be useful to individualize the allocation of prolonged ECG monitoring times, currently not routinely applied in clinical practice. Methods In a prospective multicenter study, the first analysable hour of raw ECG data from prolonged 72 hours Holter ECG monitoring in 1031 patients with acute ischemic stroke/TIA presenting in sinus rhythm was classified by an automated software (AA) into “no risk of AF” or “risk of AF” and compared to clinical variables to predict AF during 72 hours Holter‐ECG. Results pAF was diagnosed in 54 patients (5.2%; mean …
ELECTROCARDIOGRAPHIC FINDINGS IN PATIENTS WITH AMYOTROPHIC LATERAL SCLEROSIS.
2008
Impact of monitoring on detection of arrhythmia recurrences in the ESC-EHRA EORP atrial fibrillation ablation long-term registry
2019
Abstract Aims Monitoring of patients after ablation had wide variations in the ESC-EHRA atrial fibrillation ablation long-term (AFA-LT) registry. We aimed to compare four different monitoring strategies after catheter AF ablation. Methods and results The ESC-EHRA AFA-LT registry included 3593 patients who underwent ablation. Arrhythmia monitoring during follow-up was performed by 12-lead electrocardiogram (ECG), Holter ECG, trans-telephonic ECG monitoring (TTMON), or an implanted cardiac monitoring (ICM) system. Patients were selected to a given monitoring group according to the most extensive ECG tool used in each of them. Comparison of the probability of freedom from recurrences was perfo…
Clinical evaluation of a wireless ECG sensor system for arrhythmia diagnostic purposes
2013
Accepted version of an article in the journal: Medical Engineering and Physics. Also available from the publisher at: http://dx.doi.org/10.1016/j.medengphy.2013.03.002 In a clinical study, a novel wireless electrocardiogram (ECG) recorder has been evaluated with regard to its ability to perform arrhythmia diagnostics. As the ECG recorder will detect a "non-standard" ECG signal, it has been necessary to compare those signals to "standard" ECG recording signals in order to evaluate the arrhythmia detection ability of the new system. Simultaneous recording of ECG signals from both the new wireless ECG recorder and a conventional Holter recorder was compared by two independent cardiology specia…
Electrocardiographic Diagnosis of Atrial Tachycardia: Classification, P-Wave Morphology, and Differential Diagnosis with Other Supraventricular Tachy…
2015
Atrial tachycardia is defined as a regular atrial activation from atrial areas with centrifugal spread, caused by enhanced automaticity, triggered activity or microreentry. New ECG classification differentiates between focal and macroreentrant atrial tachycardia. Macroreentrant atrial tachycardias include typical atrial flutter and other well characterized macroreentrant circuits in right and left atrium. Typical atrial flutter has been described as counterclockwise reentry within right atrial and it presents a characteristic ECG “sawtooth” pattern on the inferior leads. The foci responsible for focal atrial tachycardia do not occur randomly throughout the atria but tend to cluster at chara…
Análisis de señales biomédicas para aplicación de terapias en la fibrilación ventricular cardiaca
2017
La muerte súbita es una muerte natural, inesperada y rápida en un tiempo límite de 24 horas después del comienzo de un proceso patológico. Las causas más comunes de la muerte súbita son las enfermedades Cardiovasculares (ECV) que resultan estar entre las principales causas de muerte en todo el mundo. En 2012, la Organización Mundial de la Salud (OMS) registró 17,5 millones de muertes por ECV, que representan el 31 % de todas las muertes registradas en el mundo . Una de las enfermedades cardiovasculares con mayor mortalidad es la Fibrilación Ventricular (FV), que es una arritmia cardíaca producida por una actividad eléctrica desorganizada del corazón. Durante la FV, los ventrículos se contra…
How neurophysiological measures can be used to enhance the evaluation of remote tower solutions
2019
New solutions in operational environments are often, among objective measurements, evaluated by using subjective assessment and judgment from experts. Anyhow, it has been demonstrated that subjective measures suffer from poor resolution due to a high intra and inter-operator variability. Also, performance measures, if available, could provide just partial information, since an operator could achieve the same performance but experiencing a different workload. In this study, we aimed to demonstrate: (i) the higher resolution of neurophysiological measures in comparison to subjective ones; and (ii) how the simultaneous employment of neurophysiological measures and behavioral ones could allow a…
Wireless ECG and cardiac monitoring systems: State of the art, available commercial devices and useful electronic components
2021
Abstract Wireless ElectroCardioGram (ECG) systems are employed in manifold application fields: tele-monitoring, sport applications, support to ageing people at home, fetal ECG, wearable devices and ambulatory monitoring. The presence of cables often hinders user’s free movements, alongside clinicians’ routine operations. Therefore, wireless ECG systems are desirable. This paper aims at reviewing the solutions described in the literature, besides commercially available devices and electronic components useful to setup laboratory prototypes. Several systems have been developed, different in terms of the adopted technology; when approaching the development of a wireless ECG system, some import…
Lead Reconstruction Using Artificial Neural Networks for Ambulatory ECG Acquisition
2021
One of the most powerful techniques to diagnose cardiovascular diseases is to analyze the electrocardiogram (ECG). To increase diagnostic sensitivity, the ECG might need to be acquired using an ambulatory system, as symptoms may occur during a patient’s daily life. In this paper, we propose using an ambulatory ECG (aECG) recording device with a low number of leads and then estimating the views that would have been obtained with a standard ECG location, reconstructing the complete Standard 12-Lead System, the most widely used system for diagnosis by cardiologists. Four approaches have been explored, including Linear Regression with ECG segmentation and Artificial Neural Networks (ANN). The b…
Improving diagnostic accuracy of MDCT coronary angiography in patients with mild heart rhythm irregularities using ECG editing
2006
OBJECTIVE. The objective of our study was to compare diagnostic accuracy of MDCT coronary angiography in a population of patients with mild heart rhythm irregularities before and after editing the ECG. SUBJECTS AND METHODS. Thirty-eight patients who underwent MDCT coronary angiography and conventional coronary angiography were enrolled in the study. The inclusion criterion was the presence of mild heart rhythm irregularities (i.e., premature beats; atrial fibrillation; mistriggering; or low heart rate, defined as 40 beats per minute or less) during the scan. All patients underwent MDCT with the following parameters: 16 detectors; collimation, 0.75 mm; gantry rotation time, 375 msec; 120 kV;…